7
3 Installation Instructions
3.1 Mounting
Read through the entire installation section first before beginning
installation.
Be very careful when working with batteries. Wear eye protection.
Have fresh water available to wash and clean any contact with
battery acid.
Uses insulated tools and avoid placing metal objects near the
batteries.
Explosive battery gasses may be present during charging. Be certain
there is sufficient ventilation to release the gasses.
Avoid direct sunlight and do not install in locations where water can
enter the controller.
Loose power connections and/or corroded wires may result in
resistive connections that melt wire insulation, burn surrounding
materials, or even cause fire. Ensure tight connections and use cable
clamps to secure cables and prevent them from swaying in mobile
applications.
Battery connection may be wired to one battery or a bank of batteries.
The following instructions refer to a singular battery, but it is
implied that the battery connection can be made to either one
battery or a group of batteries in a battery bank.
Select the system cables according to 3A/mm
2
current density.